Re: HERGOM L08 COOKER - LEAKY BOILER!!


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]

Posted by Harold Kestenholz - Hydronic Network on February 05, 2000 at 11:46:57:

In Reply to: HERGOM L08 COOKER - LEAKY BOILER!! posted by David Palmer (SCOTLAND - Aberdeenshire) on February 05, 2000 at 06:54:43:

There is no "safe" compund to put into a system. Anything that can stop a leak also can stop circulators and block valves. Automobiles use a sealer in some antifreeze that expands and sets in contact with air when it reaches the leaking point, somewhat like white blood cells at a skin tear. But ethylene glycol auto antifreeze is also poisonous. The old leak-stops like oatmeal and pepper do the job, but are very prone to clogging the system. Schedule a boiler replacement for the first warm day.