[an error occurred while processing this directive]
Posted by THAMIZH SELVAN.A on February 07, 2008 at 02:06:44:
OBJECTIVE
To contribute to your organization¡¦s success through the use of exceptional Engineering, Managerial and People Skills.
EMPLOYMENT HISTORY
TOTAL WORK EXPERIENCE ¡V 5 YRS 5 MONTHS.
ƒá Senior Executive ¡V Power Execution, Cethar Vessels Private Limited, Trichy, TamilNadu, India from Mar 2007 to till date
ƒá Executive Engineer ¡V Project Planning & Control, Bhatia International Limited, Maharashtra, India, from Oct 2003 to Feb 2007.
ć Graduate Apprentice Trainee, Neyveli Lignite Corporation Limited, TamilNadu, India from Sep 2002 to Sep 2003.
PROJECTS INVOLVED
ƒá Cethar Vessels Private Limited ¡V Deputed in 92 TPH, 2 x 22.3 MW CFBC boiler power plant in Binani Cements Limited, Rajasthan, India.
ƒá Bhatia International Limited ¡V 6 MTPA Coal Washery at Maharashtra, India
EDUCATION
ć Bachelor of Engineering (Mechanical)Manonmaniam Sundaranar University, TamilNadu, India
Overall Percentage: 79.09 (First Class with Distinction)
ć Master of Business Administration
ICFAI University, Hyderabad, India through Distance Education ¡V currently doing I year.
PROFESSIONAL SKILLS
TECHNICAL SKILLS
PROJECT MANAGEMENT
ć Project planning, scheduling and monitoring for set up facilities and deployment of available resources to achieve organizational objectives.
ć Overseeing procurement of materials, subcontracting agreements and site coordination.
ć Follow up of Material supply status.
ć Managing overall operations for executing the project within the preset cost and time parameters.
ć Preparing periodic reports to facilitate decision making.
ć Taking remedial actions for project delay.
ć Raising Commercial Invoices as per the break up according to the project status and its follow up.
ERECTION AND COMMISSIONING
ć Erection of all the Supporting Structure, Pressure parts and Non pressure parts, Integral Piping (IBR and Non IBR), Fans, Blowers of 2 x 22.3MW CFBC Boiler.
ć The Pressure Parts includes Steam Drum, Water Wall Panels, and Water Cooled Cyclone with Sealpot Assembly, Steam Cooled Wall Panels, Super heater coils, Economiser Coils.
ć Integral piping includes both High and Low pressure steam and water lines.
ć The Non pressure part includes Air Preheater, Fans and Ductings.
ć Erection and Commissioning of Start up ( HSD Oil ) firing system and its HSD Oil piping.
ć Ensuring the Quality of Erection.
ć Refractory and Insulation application of the above.
ć Conducting pre commissioning activities like Hydraulic Test as per IBR formalities, Refractory Dry Out, Slow Firing and Alkali Boil out of CFBC boiler.
ć Planning Material Handling activities to facilitate the erection.
ƒá Verification and approval of contractors¡¦ bills.\
ACADEMIC PROJECT WORKS
ć Title: Design and Analysis of Circumferential Lugs in Power Boilers Using ANSYS in Bharath Heavy Electricals Limited, Trichy.
ć Title: Fabrication of Hydraulic Brake Test Bench and Modified Circuit for testing Relay Emergency Valve in Neyveli Lignite Corporation Limited, Neyveli.
ADDITIONAL QUALIFICATIONS
ć Computer proficiency: MS word, Ms Office, Ms Excel, Ms PowerPoint and AutoCAD.
ć Attended Self Development Classes on Human Relations, Financial Management, Personality Development and Management Information System, and Management by Objectives.
ƒá In-Plant Training in ¡¥The Tuticorin Thermal Power Station¡¦, Tuticorin, India
AREA OF SPECIALIZATION
ć Project Management.
ć Production Planning and Control.
ć Human Resources Management.
AWARDS AND ACHIEVEMENTS
ƒá Member of ¡§Indian Society of Mechanical Engineers¡¨
ć Awarded as the Best Outgoing Student in the college for the year of 2002.
PERSONAL DETAILS
DOB-26/01/1981 Passport Details
Passport No: E 4985586
Valid up to: 12/03/2013
Gender-Male
Contact Address:
F-10, Mahalakshmi Flats,Jafferkhanpet, Chennai,
TamilNadu¡V 600 083, India.
Contact No-+91-99296 38841