[an error occurred while processing this directive]
Posted by Joe Brix on October 22, 2007 at 19:22:11:
In Reply to: utica vs peerless boilers posted by kevin harney on October 22, 2007 at 18:37:01:
Both are good units. But for such a small house. a WGO-3 seems large. Both models come in smaller 2 section versions but they have a tendency to soot up faster with such small combustion chambers. I would suggest a smaller 3 pass scotch marine style boiler. Such as the Burnham MPO, Biasi, WH ultra oil or buderus G115.