[an error occurred while processing this directive]
Posted by HeatPro on March 05, 2007 at 13:07:22:
In Reply to: Re: Old weil-Mclain boiler posted by Andrew on March 05, 2007 at 11:51:22:
Speaks good of the old boiler. It's been subjected to low temperatures; but the thick casting has kept the fireside above condensing temperature, so it didn't rust out. Reping to a boiler subloop as in Weil's new system piping arrangements can help keep the boiler temp a bit higher. They are on-line on Weil sites Installation Instructions.