[an error occurred while processing this directive]
Posted by HeatPro on September 16, 2006 at 11:28:17:
In Reply to: Very old Weil McLain Boiler Leaks @ evaporator tank. posted by Joe T RI on September 16, 2006 at 09:28:22:
Seems you are describing a side-arm heater. They weren't very efficient and the disconnected tubing implies it isn't being used. so eliminating it is the next step. Find out where your hot water is being made and decide if you want to continue using that or to get an indirect water heater.
Continue to let fresh water come into the boiler to replace tha being lost from drips and you will have to buy a new boiler as well.