[an error occurred while processing this directive]

Re: Question on Boiler


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Forum #2 ] [ FAQ ]

Posted by Harold hydronicnetwork.net on January 09, 2004 at 16:18:32:

In Reply to: Question on Boiler posted by Pat on January 09, 2004 at 14:15:49:

You just didn't notice before. Boiler-heated baseboard had been designed to give off heat at 180F or above for more than half a century. Before that steam heated radiators at 215F. It is only within the past 20 years that it has been common to provide heat at 140F or less water temperatures.

If you don't like the radiation getting that hot, double the length of the baseboard and it will only have to get to 140F to heat your home.


Follow Ups:



Post a Followup

Name:
E-Mail:

Subject:

Comments: