Posted by Harold hydronicnetwork.net on December 24, 2003 at 17:26:55:
In Reply to: Weil-McLain Gold GV4 boiler gets stuck in purge cycle posted by BobB on December 21, 2003 at 20:48:07:
A corroded vent would change the burner pressure relationships and could contribute to the problem.
It may be associated to the other post:
http://www.boilerroom.com/wwwboard/home/6596.shtml