Posted by jtown on October 12, 2001 at 17:16:55:
In Reply to: Water in oil for oil fired steam boiler posted by Richard Bradley on October 12, 2001 at 08:34:56:
Don't run it through a pump. It will mix it and make it milky (emulsified) if you have a return oil line to the tank you will be mixing it up. Try running a short tube from the tank into a jug. You probably need to get ahold of a flaring tool. Be careful, it is easy to make a mess. Have a bag of kitty litter (powdered clay) on hand to soak up any spill.