Re: Single water hammer bang


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]

Posted by Ralph Slate on January 25, 2000 at 17:41:49:

In Reply to: Re: Single water hammer bang posted by Harold Kestenholz - Hydronic Network on January 18, 2000 at 19:53:17:

That is exactly what it was -- the single knock (and several other radiators with a few knocks during the cycle) were dragging across the wood floor as they expanded. But they didn't drag smoothly -- it was like a mini-earthquake, when enough force built up the radiator slid a little bit causing a bang.

I put some of those pads that you use on the bottom of furniture to stop it from scratching your wood floors, and the knocks went away like magic.

Ralph