Re: Where can I purchase steam baseboards?


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]

Posted by Tim Hodgson on March 18, 2000 at 15:22:18:

In Reply to: Where can I purchase steam baseboards? posted by Michele on March 13, 2000 at 10:40:50:

: I live in Northern NJ and would like to replace one of my radiators with steam baseboard. Does anyone know where I could purchase steam baseboards? Any company or store names would be appreciated. Thanks.
Burnham makes a cast iron baseboard that can be used for steam, however the piping of the steam trap needs to be changed. The trap should be installed 12" below the baseboard. I'm sure there is a local Burnham rep in your area. Good luck, Tim