Re: Radiator Sealant


[ Follow Ups ] [ Post Followup ] [ Boiler Room Residential and Home Steam-Forum ] [ FAQ ]

Posted by Harold Kestenholz - Hydronic Network on December 21, 2000 at 09:22:04:

In Reply to: Radiator Sealant posted by James on December 21, 2000 at 08:54:04:

Cast-iron baseboard sections are connected by a tapered sleeve (push-nipple) squeezed between sections. The nipple has permitted water to pass, so the nipple or the casting is damaged at that point. Call a plumber to remove, disassemble, inspect and reseal the radiation. Putting sealant in the hole can also send the sealant back into the boiler water to seal something else.